Digiplex & DigiplexNE - 5 - Modules Programming Guide
LCD Keypad Module
The keypad’s serial number can be found on the keypad’s PC board. The keypad’s serial number can also be viewed by pressing and holding the [0] key,
entering the [
INSTALLER CODE] and then entering section [000].
U = Default setting
SECTION [001] : Keypad Partition Assignment
SECTION [002]: Future Use
Option OFF ON Option OFF ON
[1]
Partition 1 N Disabled
U Enabled
[1]
Future Use N N/A N N/A
[2] Partition 2 N Disabled
U Enabled
[2]
Future Use N N/A N N/A
[3] Partition 3 N Disabled
U Enabled
[3]
Future Use N N/A N N/A
[4] Partition 4 N Disabled
U Enabled
[4]
Future Use N N/A N N/A
[5] Partition 5
(DGP-NE96 only) N Disabled
U Enabled
[5]
Future Use N N/A N N/A
[6] Partition 6
(DGP-NE96 only) N Disabled
U Enabled
[6]
Future Use N N/A N N/A
[7] Partition 7
(DGP-NE96 only) N Disabled
U Enabled
[7]
Future Use N N/A N N/A
[8] Partition 8
(DGP-NE96 only) N Disabled
U Enabled
[8]
Future Use N N/A N N/A
SECTION [003]: General Options 1 SECTION [004]: General Options 2
Option OFF ON Option OFF ON
[1] Display code entry
U Disabled
N Enabled [1] Muting
U Disabled
N Enabled
[2] Display exit delay
U Disabled
N Enabled [2] Exit Delay Beep N Disabled
U Enabled
[3] Display entry delay
U Disabled
N Enabled [3]
Future Use N N/A N N/A
[4] Confidential Mode
(not for UL installations)
U Disabled
N Enabled [4] Chime on Zone Closure
U Disabled
N Enabled
[5] To exit Confidential Mode
U
Enter code
N
Press Button
[5]
Future Use N N/A N N/A
[6] Future Use N N/A N N/A [6] Future Use N N/A N N/A
[7] Future Use N N/A N N/A [7] Future Use N N/A N N/A
[8] Time display option
U
yy/mm/dd
N dd/mm/yy [8]
Future Use N N/A N N/A
SECTION [005] : Beep on Trouble
SECTION [006]: PGM and Tamper Options
Option OFF ON Option OFF ON
[1] System & Clock Trouble Beep
U Disabled
N Enabled
[1] PGM State
U N.O.
N N.C.
[2] Communicator Trouble Beep
U Disabled
N Enabled
[2] PGM Deactivation Mode
U
Deactiva-
tion Event
N PGM Timer
[3] Module & Combus Trouble Beep
U Disabled
N Enabled
[3] PGM Base Time
U 1 second
N 1 minute
[4]
All Zone Trouble Beep
U Disabled
N Enabled
[4] PGM Override
U Disabled
N Enabled
[5] to [8]
Future Use N N/A N N/A [5] Keypad Tamper
U Disabled
N Enabled
[6] to [8]
Future Use N N/A N N/A
DGP2-641
Vista de pagina 0
1 2 3 4 5 6 ... 12 13

Indice de contenidos

Pagina 1 - LCD Keypad Module

Digiplex & DigiplexNE - 5 - Modules Programming GuideLCD Keypad ModuleThe keypad’s serial number can be found on the keypad’s PC board. The k

Pagina 2 - MESSAGE PROGRAMMING

Digiplex & DigiplexNE - 43 - Modules Programming Guide040Fail to Communicate on telephone Number000 Telephone Number 001 to 004 001 to 004255

Pagina 3 - COMBUS VOLTMETER

Digiplex & DigiplexNE - 44 - Modules Programming Guide048 (cont’d) Keyswitch/Utility Key Pressed000Keyswitch Input 27* 027 027Keyswitch Input 28

Pagina 4 - Module Connection Drawings

Digiplex & DigiplexNE - 45 - Modules Programming GuideNOTE 1: 000 = Occurs in all partitions enabled in the system (refer to the appropriate con

Pagina 5 - LCD KEYPAD MODULE (DGP2-641)

PRINTED IN CANADA 05/2003 MODULES-EP05

Pagina 6 - Appendix 1: Programming PGMS

Digiplex & DigiplexNE - 6 - Modules Programming GuideOnly Event Groups 000 to 055 and 070 can be used to program the module’s PGM. Refer to “App

Pagina 7

Digiplex & DigiplexNE - 7 - Modules Programming GuideTable 3: Special CharactersUSING THE MEMORY KEYDownload Contents of the Memory Key to th

Pagina 8

Digiplex & DigiplexNE - 29 - Modules Programming GuideModule Connection DrawingsMODULE CONNECTION OVERVIEW

Pagina 9

Digiplex & DigiplexNE - 31 - Modules Programming GuideLCD KEYPAD MODULE (DGP2-641)

Pagina 10

Digiplex & DigiplexNE - 39 - Modules Programming GuideAppendix 1: Programming PGMSA PGM is a programmable output that toggles to its opposite

Pagina 11

Digiplex & DigiplexNE - 40 - Modules Programming Guide004 (cont’d) Non-reportable Event000NEware User Login 010 010NEware User Logout 011 011Use

Pagina 12 - CLEAR] and [0]

Digiplex & DigiplexNE - 41 - Modules Programming Guide015 Disarm with Keyswitch000 Keyswitch numbers 001 to 032 001 to 032255 Any keyswitch N

Pagina 13

Digiplex & DigiplexNE - 42 - Modules Programming Guide030 Special Alarm000Emergency Panic (Keys 1 & 3) 000 000Medical Panic (Keys 4 & 6)

Comentarios a estos manuales