4 User’s Manual
2.0 BASIC OPERATION
The system communicates by illuminating the “AC” light, the “Status”
light and the various lights on the screen as shown in figure 1.
Figure 1: Keypad Overview
[Enter] Saves current data and exits current menu.
[Clear] Erases current data entry or reverts to the preceding step.
Area Lights: (A1, A2, A3 and A4)
ON = Area armed
OFF = Area disarmed
FLASH = Area in alarm
Action Lights: (Access, Stay,
Force, Mem, Trbl and Prg)
Lights will illuminate according
to the status of the system.
Numerical Lights: (Zones)
ON = Zone is open
OFF = Zone is closed (OK)
FLASHES = Zone / fire loop
“AC” Light:
ON = AC Power (OK)
OFF = Power failure
“Status” Light:
When green:
ON = All zones closed
OFF = Zone(s) open
FLASH = Exit Delay in progress
When red:
ON = All areas armed
OFF = Area disarmed
FLASH = Areas in alarm
Keypad will display the status
of all its assigned areas.