SEKURE Paradox Digiplex DGP-610 Guía de instalación Pagina 33

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 32
EVO Control Panel 29
12 Programmable Outputs
The control panel provides a maximum of 100 mA to PGM1 to PGM4.
PGM5 is a 5A/28Vdc N.O./ N.C. relay output. Activating a PGM changes
it’s state from open to closed or closed to open. Refer to section 2.8 on
page 2.
12.1 PGM Activation Event
The PGM Activation Event determines which event will activate the PGM.
The Event Group specifies the event, the Feature Group identifies the
source, and the Start # and End # sets the range within the Feature Group
(see PGM Programming Table in the "EVO Programming Guide").
Enter the sections that correspond to the Event Group, Feature Group,
Start # and End # of the desired PGM and enter the desired 3-digit number
from the PGM Programming Table:
12.2 PGM Deactivation Option
Once the PGMs are activated, they can deactivate when another event
occurs or after a period of time. Enter the section that corresponds to the
desired PGM and enable or disable option [1] (default = PGM Deactivation
Event):
12.3 Flexible PGM Deactivation Option
The PGM Deactivation Option must be set to PGM Timer for this feature to
function. The Flexible PGM Deactivation Option uses both the PGM
Deactivation Event and the PGM Timer. When enabled, and if the PGM is
activated, it will deactivate when either the PGM Deactivation Event occurs
or the PGM Timer elapses, whichever happens first.
Enter the section corresponding to the PGM and enable option [3]
(default = disabled):
12.4 PGM Deactivation Event
The PGM Deactivation Event determines which event will return the PGM
to its original state. The Event Group specifies the event, the Feature Group
identifies the source, and the Start # and End # determine the range within
the Feature Group.
Enter the sections that correspond to the Event Group, Feature Group,
Start # and End # of the desired PGM and enter the desired 3-digit number
from the PGM Programming Table.
12.5 PGM Timer
When the PGM Deactivation Option is enabled, the PGM Timer determines
how many seconds or minutes the PGM remains activated.
Enter the section that corresponds to the desired PGM and enter a value
from 001 to 255 (default = 005). The value entered is either in seconds or
minutes as determined by the PGM Time Base Selection:
12.5.1 PGM Time Base Selection
The PGM Time Base Selection determines whether the PGM Timers are in
minutes or seconds (default = seconds):
12.6 PGM1 Becomes a 2-wire Smoke Detector Input*
SECTION [3030]: OPTION [1]
(default = disabled) When enabled, PGM1 acts as a zone input for two-
wire smoke detectors. When programming Zone Numbering (see section
4.2 on page 10), the control panel will recognize PGM1 as input number
255. Please refer to section 2.16.1 on page 7 for connection information.
* UL Note: Not verified by UL.
12.7 PGM Test Mode
Entering sections [0901] to [0903] activates the corresponding PGM for 8
seconds to verify if the PGM is functioning as desired.
12.8 PGM Initial Status
Use this option to set the initial state for the PGM.
Event Group Feature Group Start # End #
PGM 1: [0910] [0911] [0912] [0913]
PGM 2: [0920] [0921] [0922] [0923]
PGM 3: [0930] [0931] [0932] [0933]
PGM 4: [0940] [0941] [0942] [0943]
PGM 5: [0950] [0951] [0952] [0953]
PGM 1: [0919] Option Feature
PGM 2: [0929] [1] ON PGM Timer
PGM 3: [0939] [1] OFF PGM Deactivation Event
PGM 4: [0949] [4] ON Normally Closed
PGM 5: [0959] [4] OFF Normally Open
PGM 1: [0919] PGM 2: [0929] PGM 3: [0939]
PGM 4: [0949] PGM 5: [0959]
Event Group Feature Group Start # End #
PGM 1: [0914] [0915] [0916] [0917]
PGM 2: [0924] [0925] [0926] [0927]
PGM 3: [0934] [0935] [0936] [0937]
PGM 4 [0944] [0945] [0946] [0947]
PGM 5 [0954] [0955] [0956] [0957]
PGM 1: [0918] PGM 2: [0928] PGM 3: [0938]
PGM 4: [0948] PGM 5: [0958]
PGM 1: [0919]
Option Feature
PGM 2: [0929]
[2] ON Minutes
PGM 3: [0939]
[2] OFF Seconds
PGM 4: [0949]
PGM 5: [0959]
PGM 1: [0901] PGM 2: [0902] PGM 3: [0903]
PGM 4: [0904] PGM 5: [0905]
PGM 1: [0919] Option Feature
PGM 2: [0929] [4] ON Normally Closed
PGM 3: [0939] [4] OFF Normally Open
PGM 4: [0949]
PGM 5: [0959]
Vista de pagina 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 63 64

Comentarios a estos manuales

Sin comentarios