46 Reference & Installation Manual
3.3.12 Keypad Tamper Enable
SECTION [006]: OPTION [5]
3.3.13 Combus Voltmeter
1. From Normal Mode press and hold the [0] key.
2. Enter the [
INSTALLER CODE] (Default: 000000).
3. Press [
ACC].
The voltage may drop during the control panel battery test.
3.4 Programmable Output Options
3.4.1 PGM State
SECTION [006]: OPTION [1]
The PGM can provide 50mA to any device connected to it.
3.4.2 PGM Deactivation Mode
SECTION [006]: OPTION [2]
3.4.3 PGM Base Time
SECTION [006]: OPTION [3]
3.4.4 PGM Override
SECTION [006]: OPTION [4]
When the PGM override is enabled, the keypad's on-board PGM will ignore
PGM Activation Events (section 3.4.6), PGM Deactivation Events (section
3.4.7), and PGM Timers (section 3.4.5). It will remain in its normal state
until the PGM Override is disabled. This option may be used to test the
PGM connections.
3.4.5 PGM Timer
SECTION [008]
The value programmed in section [008] represents how long the PGM will
remain in its opposite state after being activated. To program the timer,
enter a 3-digit decimal value (000 to 255) in section [008]. Default: 5
seconds.
3.4.6 PGM Activation Event
SECTIONS [009] TO [012]
Enter the sections that correspond to the Event Group, Feature Group,
Start # and End # of the PGM and enter the required data.
3.4.7 PGM Deactivation Event
SECTIONS [013] TO [016]
If the PGM Deactivation Option is set to follow the PGM Deactivation event,
the PGM will return to its normal state when the event programmed in
sections [013] to [016] occurs.
Enter the sections that correspond to the Event Group, Feature Group,
Start # and End # of the PGM and enter the required data.
3.5 EVO641R Programming
3.5.1 Partition Assignment
SECTION [001]: OPTIONS [1] TO [8]
To assign the keypad to a partition, enable the option that corresponds to
the desired partition. By default, partitions 1 to 8 are enabled.
3.5.2 Display Access Code Entry
SECTION [003]: OPTION [1]
Option [1] OFF=Digits are replaced by a “*“(default)
Option [1] ON=Access Code digits will be displayed
3.5.3 Display Exit Delay Timer
SECTION [003]: OPTION [2]
Option [2] OFF=Will not display Exit Delay timer (default)
Option [2] ON=LCD screen will display Exit Delay timer
3.5.4 Display Entry Delay Timer
SECTION [003]: OPTION [3]
Option [3] OFF=Will not display the Entry Delay Timer (default)
Option [3] ON=LCD screen will display Entry Delay Timer
3.5.5 Confidential Mode
SECTION [003]: OPTIONS [4] AND [5]
Section [003]:
Option [4] OFF=Normal Mode (default)
Option [4] ON=Confidential Mode
Option [5] OFF=LCD screen activated by entering an access code (default)
Option [5] ON=LCD screen activated by pressing a button
3.5.6 Confidential Mode Timer
SECTION [007]
Section [007] determines the amount of time without action before the
keypad enters Confidential Mode. The Confidential Mode Timer can be set
from 005 seconds to 255 seconds. Default: 120 secs.
3.5.7 Time Display Option
SECTION [003]: OPTION [8]
Option [8] OFF=Date displayed as yy/mm/dd (default)
Option [8] ON=Date displayed as dd/mm/yy
3.5.8 Muting
SECTION [004]: OPTION [1]
Option [1] OFF=Audible sounds (default)
Option [1] ON=Mute
3.5.9 Beep on Exit Delay
SECTION [004]: OPTION [2]
Option [2] OFF=Exit Delay beep disabled
Option [2] ON=Exit Delay beep enabled (default)
3.5.10 Chime on Zone Closure
SECTION [004]: OPTION [4]
Option [4] OFF=Chime on Zone Closure disabled (default)
Option [4] ON=Chime on Zone Closure enabled
Option [3] ON = Beep enabled: Module and Bus Troubles
Option [4] OFF = Beep disabled: all Zone Troubles (default)
Option [4] ON = Beep enabled: all Zone Troubles
Option [5] OFF = Keypad's tamper is disabled (default)
Option [5] ON = Keypad's tamper is enabled
Option [1] OFF= PGM is Normally Open (default)
Option [1] ON= PGM is Normally Closed
Option [2] OFF = Deactivates on PGM Deactivation Event (default)
Option [2] ON = PGM will deactivate according to the PGM Timer
Option [3] OFF = PGM Base Time is 1 second (default)
Option [3] ON = PGM Base Time is 1 minute
Option [4] OFF = PGM Override disabled (default)
Option [4] ON = PGM Override enabled
Event Group Feature Group Start # End #
PGM
[009] [010] [011] [012]
Event Group Feature Group Start # End #
PGM
[013] [014] [015] [016]