SEKURE Paradox Spectra 1686H Manual de instalación Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 60
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
SPECT RA SERIES 9
2.11 KEYPAD AND KEYPAD ZONE CONNECTIONS
To connect the keypads to the control panel, remove the back cover and wire the GRN, YEL, RED, and BLK
terminals of each keypad to the corresponding terminals on the control panel as shown in Figure 2.1 on page 4 or
Figure 2.2 on page 5. There is no limit to the number of keypads that can be connected to the control panel so long
as the current consumption does not surpass 700mA. For details on Keypad Tamper Supervi sion see section 10.8
on page 40.
Each keypad has one zone input terminal, allowing you to connect one motion detector or door contact directly to a
keypad. The keypad can then communicate the status of the zone to the control panel. A maximum of two keypad
zones can be used with each control panel. After connecting the device, the zone's parameters must be defined. For
details on zone recognition and Zone Programm ing refer to page 16. Also, refer to the feature Reassign Keypad
Zone 2 on page 16.
Example: A door contact located at the entry point of an establishment can be wired directly to the input terminal of
the entry point keypad instead of wiring the door contact all the way to the control panel.
Figure 2.7: Keypad Zone Connections
When a 1641 LCD keypad is connected to Spectra, the Keypad Zone Sending option (Option [2] key [1])
determines whether the status of the keypad zone will be transmitted to the control panel. The Keypad Zone
Sending option of the 1641 keypad must be enabled during the following conditions:
If you are using both keypad zones and at least one is from a 1641 keypad.
If you are using the keypad zones of other types of keypads, such as a 1686H 10-zone LED keypad,
and the keypad zone definition of the 1641 keypad (keypad zone 1 or keypad zone 2; Option [2] key [3])
matches that of another connected keypad.
2.12 KEYSWITCH CONNECTIONS
Keyswitches allow users to arm or disarm a partition by pushing a button or by
activating a switch with a key. Connect the keyswitch as shown in Figure 2.8
directly to the control panel terminals. Once a keyswitch is connected, it must be
assigned to a zone and its parameters must be programmed (see Zone
Programming on page 16 and Keyswitch Options on page 22).
Fi
gure
2
.
8
:
K
eysw
it
c
h
Vista de pagina 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 59 60