8 REFERENCE & INSTALLATION MANUAL
Figure 2-6: Single Zone Input Connections
2.14 DOUBLE ZONE CONNECTIONS
Enabling the ATZ feature (see section 4.2) allows you to install two
detection devices per input terminal. Connect the devices as shown in
Figure 2-7. Devices connected to input terminals must be assigned to a
zone and the zone's parameters must be defined (see Zone Programming
on page 12). For UL listed Burglary System installations only, use EOL
resistor part #2011002000.
Figure 2-7: Double Zone Connections
2.15 CONNECTING THE DGP2-ZX4
The 4-Zone Expansion Plug-in Device* (DGP2-ZX4*) provides four
additional hardwired input terminals (8 zones with ATZ enabled). It
connects directly to the control panel through its on-board
EXPANSION
connector as shown in Figure 2-3: on page 5. Connect detection devices to
the DGP2-ZX4's terminals in the same way that they are connected to the
control panel as shown in Figure 2-6 or Figure 2-7 on page 8. Devices
connected to hardwired input terminals must be assigned to a zone and the
zone's parameters must be defined (Zone Programming on page 12). For
the 4-Zone Expansion Module (APR3-ZX4), refer to the DigiplexNE
Modules Programming Guide.
* Do not use with UL Listed systems.
Enable ATZ (see section 4.2 on page 13)
and connect as follows (extra input
cannot be used)