42 REFERENCE & INSTALLATION MANUAL
15 USER FEATURES
15.1 REGULAR ARMING
This method is used for the everyday arming of the system. All zones within
the partition must be closed to arm the system. The system can also be
Regular Armed by using a One-touch Feature (see section 6.15) or a
Keyswitch (see section 5.4.3). All users are able to Regular Arm the
partition(s) assigned to their User Access Codes. Refer to How to Arm on
page 42 for information on how to Regular Arm the system.
15.2 STAY ARMING
Stay Arming partially arms the partition to permit the user to remain in the
partition. Stay Zones (see section 4.5.3) will not arm when Stay Arming.
Partitions can also be armed by the Stay Arm One-touch Feature (see
section 6.15) or a Keyswitch (see section 5.4.4). Only User Access Codes
with the Stay and Instant Arm option enabled can Stay Arm a partition.
For example, arm the doors and windows without arming the motion
detectors. Refer to How to Arm on page 42 for information on how to Stay
Arm the system.
15.2.1 Stay Arming with Delay
Stay Arming with Delay functions like Stay Arming except armed zones are
programmed with an Entry Delay Timer (see section 4.3.14). If a zone is
triggered, the delay starts allowing the user time to disarm the partition(s).
15.3 INSTANT ARMING
Similar to Stay Arming, Instant Arming partially arms the partition to permit
the user to remain in the partition, but all Delay zones become Instant
zones. Partitions can also be armed by the Instant One-touch Feature (see
section 6.15) or a Keyswitch (see section 5.4.6). Only User Access Codes
with the Stay and Instant Arm option enabled can Instant Arm a partition.
Refer to How to Arm on page 42 for information on how to Instant Arm the
system.
15.3.1 Instant Arming with Delay
Instant Arming with Delay functions like Instant Arming except armed zones
are programmed with an Entry Delay Timer (see section 4.3.14). If a zone
is triggered, the delay starts allowing the user time to disarm the partitions.
15.4 FORCE ARMING
Force Arming allows the user to arm a partition when Force zones are open
(see section 4.5.4). Once the open zone in an armed partition is closed, the
system will then arm it as well. This feature is commonly used when a
motion detector is protecting an area that is occupied by a keypad. The
system can also be Force Armed by using a One-touch Feature (see
section 6.15) or a Keyswitch (see section 5.4.5). Only User Access Codes
with the Force Arm option enabled can Force Arm a partition.
For example, during Force arming the motion detector remains unarmed
until the user exits the area. The system will then arm the motion detector.
Refer to How to Arm on page 42 for information on how to Force Arm the
system.
15.5 HOW TO ARM
The following section details how to arm the system using an LCD or
Grafica keypad.
For LCD Keypads: To arm, users:
1) Enter their [
ACCESS CODE].
2) Press the key corresponding to the desired arming method (see
Table 13 on page 42). If the users have access to more than one
partition, they can press the key(s) corresponding to the desired
partition(s) or press [0] to arm all their assigned partitions.
For Grafica Keypads: To arm, users...
1) Enter their [
ACCESS CODE].
2) Using the scroll keys, highlight the desired arming method (see
Table 13 on page 42) and then press the center action key (Ok). If the
users have access to more than one partition, proceed to step 3.
3) Highlight either Arm All Areas or Select Area(s) and then press the
center action key (Ok). If the user(s) selected the Select Area(s)
method, follow steps 4 and 5.
4) Highlight a partition you wish to arm and then press the left action key
(Select). Repeat this step for any additional partition.
5) Press the center action key (Arm).
15.6 DISARMING
All users can disarm, except users with Arm Only (see section 12.5)
enabled on their User Access Codes. Users can only disarm the partitions
assigned to their User Access Codes. The Stay or Instant Armed partitions
can also be Disarmed by using a One-touch Feature. To disarm, users...
For LCD Keypads:
1) Enter through a designated entry. The Entry Delay Timer will begin.
2) Enter their [
ACCESS CODE].
3) Press the [
DISARM] key. If the users have access to more than one
partition, they can press the key corresponding to the desired partition
or press [0] to disarm all their assigned partitions.
For Grafica Keypads:
1) Enter through a designated entry. The Entry Delay Timer will begin.
2) Enter their [
ACCESS CODE].
3) Using the scroll keys, highlight Disarm and then press the center
action key (Ok). If you have access to more than one area, proceed to
step 4.
4) Highlight either Disarm All Areas or Select Area(s) and then press
the center action key (Ok). If you selected the Select Area(s) method,
follow steps 5 and 6.
5) Highlight the area you wish to disarm and then press the left action
key (Select). Repeat this step for any additional area.
6) Press the center action key (Disarm).
15.7 BYPASS PROGRAMMING
Bypass Programming allows users to program the security system to ignore
specified zones the next time the partition is armed. To bypass a zone, the
zone must have the Bypass option enabled, the User Access Code must
have the Bypass option enabled, and the zone must be within the User
Access Code’s partition assignment. To Bypass, users...
For LCD Keypads:
1) Enter their [
ACCESS CODE].
2) Press the [
BYP] key.
3) Enter the zone’s 2-digit number or use the [
S] and [T] keys and
press the [
BYP] key when the zone appears on-screen.
4) Press [
ENTER] key to exit.
For Grafica Keypads:
1) Enter their [
ACCESS CODE].
Table 13: Arming Methods
Arming Method LCD Grafica
Regular [ARM]
(Arm System)
Stay [STAY]
(Stay Arm)
Instant [5]
(Instant Arm)
Force [FORCE]
(Force Arm)