Digiplex DGP-NE96 - 15 - Programming Guide
Programmable Outputs
PGM Test Mode
PGM Delay
PGM Options
In order to use the Flexible PGM Deactivation Option (option [3]), the PGM Deactivation After Option (option [1]) must be ON.
PGM Programming
Section Description
[0901] Test PGM1: Activates PGM1 for 8 seconds to verify if the PGM is functioning correctly.
[0902] Test PGM2: Activates PGM2 for 8 seconds to verify if the PGM is functioning correctly.
[0903] Test PGM3: Activates PGM3 for 8 seconds to verify if the PGM is functioning correctly.
Section Data Description Default
[0918] __/__/__ ( 001 to 255 x 1 sec./mins.) PGM1 Delay
(refer to section [0919] option [2] to see whether the delay is in seconds or minutes) 5 secs./mins.
[0928] __/__/__ ( 001 to 255 x 1 sec./mins.) PGM2 Delay (refer to section [0929] option [2] to see whether the delay is in seconds or minutes) 5 secs./mins.
[0938] __/__/__ ( 001 to 255 x 1 sec./mins.) PGM3 Delay
(refer to section [0939] option [2] to see whether the delay is in seconds or minutes) 5 secs./mins.
PGM1
[0919]
PGM2
[0929]
PGM3
[0939]
Option
(
= Default Setting)
OFF
Disabled
ON
Enabled
OFF
Disabled
ON
Enabled
OFF
Disabled
ON
Enabled
[1] PGM Deactivation After (OFF = Deactivation Event; ON = PGM Timer)
N
N
N
[2] PGM Base Time
(OFF = Seconds; ON = Minutes)
N
N
N
[3] Flexible PGM Deactivation Option (OFF = PGM Timer Only; ON = PGM Timer and/or Deactivation Event)
N
N
N
[4] to [8] Future Use N/A N/A N/A N/A N/A N/A
Event Group Feature Group Start # End #
Section Section Section Section
PGM Activation PGM1 [0910] __/__/__ [0911] __/__/__ [0912] __/__/__ [0913] __/__/__
PGM2 [0920] __/__/__ [0921] __/__/__ [0922] __/__/__ [0923] __/__/__
PGM3 [0930] __/__/__ [0931] __/__/__ [0932] __/__/__ [0933] __/__/__
PGM Deactivation PGM1 [0914] __/__/__ [0915] __/__/__ [0916] __/__/__ [0917] __/__/__
PGM2 [0924] __/__/__ [0925] __/__/__ [0926] __/__/__ [0927] __/__/__
PGM3 [0934] __/__/__ [0935] __/__/__ [0936] __/__/__ [0937] __/__/__
Event Group Event Feature Group Feature Start # End #
000 Zone is OK
000
255 = any Zone #
Zone Numbers
001 to 096 001 to 096
001 Zone is Open 001 to 096 001 to 096
002 Zone is Tampered 001 to 096 001 to 096
003 Zone is in Fire Loop Trouble 001 to 096 001 to 096
004 Non-reportable Event 000
TLM Trouble (See NOTE 3 on
page 21)
000 000
Smoke detector reset 001 001
Arm with no entry delay 002 002
Arm in Stay mode 003 003
Arm in Away mode 004 004
Full arm when in Stay mode 005 005
Voice module access 006 006
Remote control access 007 007