Digiplex DGP-NE96 - 30 - Programming Guide
= Default setting
Dialer Options
= Default setting
SECTION [3032] : Partition Options 2 SECTION [3033] : System Options 2
Option
OFF ON
Option
OFF ON
[1] Bell/siren output in partition 1 N Disabled
Enabled
[1] Multiple actions in user menu
Disabled
N Enabled
[2] Bell/siren output in partition 2
Disabled
N Enabled [2] User code length
Fixed
N Flexible
[3] Bell/siren output in partition 3
Disabled
N Enabled [3] User code length (if option [2] OFF)
4-digits
N 6-digits
[4] Bell/siren output in partition 4
Disabled
N Enabled [4] Power save mode N Disabled
Enabled
[5]
Bell/siren output in partition 5
Disabled
N Enabled
[5]
Bypass not displayed while system
is armed
N Disabled
Enabled
[6] Bell/siren output in partition 6
Disabled
N Enabled [6] Trouble Latch
Disabled
N Enabled
[7] Bell/siren output in partition 7
Disabled
N Enabled [7] EOL resistor on hardwire zones
Disabled
N Enabled
[8] Bell/siren output in partition 8
Disabled
N Enabled [8] (ATZ) Zone Doubling
Disabled
N Enabled
SECTION [3034] : System Options 3 SECTION [3035] : System Options 4
Option
OFF ON
Option
OFF ON
[1]&[2] Wireless Transmitter Supervision
Options (see table below)
N
See Table
N
See Table
N
See Table
N
See Table
[1] Restrict arming on AC failure
Disabled
N Enabled
[2]
Restrict arming on battery failure
Disabled
N Enabled
[3]
Generate supervision failure if
detected on a bypassed wireless zone
Yes
N No [3] Restrict arming on bell or auxiliary
failure
Disabled
N Enabled
[4] Restrict arming on a wireless
transmitter supervision failure
Disabled
N Enabled [4] Restrict arming on TLM failure
Disabled
N Enabled
[5]&[6] Zone & Module Tamper Recognition
Options (see table below)
N
See Table
N
See Table
N
See Table
N
See Table
[5] Restrict arming on module
troubles
Disabled
N Enabled
[6] Account Number Transmission
Partition #
N Tel #
[7] Generate tamper if detected on
bypass zone
NYes
No
[7] Transmit zone status on serial port
Disabled
N Enabled
[8]
Restrict arming on tamper trouble
Disabled
N Enabled
[8] Serial Port Baud Rate
19,200
N 38,400
Wireless Transmitter Supervision Options
(Section [3034]; options [1] & [2])
Zone & Module Tamper Recognition Options
(Section [3034]: options [5] & [6])
[1] [2] [5] [6]
OFF OFF - Disabled (default) OFF OFF - Disabled (default)
OFF ON -
GENERATES TROUBLE ONLY (WHEN ARMED OR DISARMED)OFFON- GENERATES TROUBLE ONLY (WHEN ARMED OR DISARMED)
ON OFF - When disarmed:
GENERATES TROUBLE ONLY ON OFF - When disarmed: GENERATES TROUBLE ONLY
- When armed: Follows Zone Alarm Types (page 7) - When armed: Follows Zone Alarm Types (page 7)
ON ON - When disarmed: GENERATES AUDIBLE ALARM ON ON - When disarmed: GENERATES AUDIBLE ALARM
- When armed: Follows Zone Alarm Types (page 7) - When armed: Follows Zone Alarm Types (page 7)
SECTION [3036]: Dialer Options 1 SECTION [3037] : Dialer Options 2
Option
OFF ON
Option
OFF ON
[1]&[2]
Telephone Line Monitoring (TLM) -
(see table on page 29)
N
See Table
N
See Table
N
See Table
N
See Table
[1] Call back
Disabled
N Enabled
[2] Automatic event buffer transmission
Disabled
N Enabled
[3] Dialer (reporting to monitoring
station)
Disabled
NEnabled [3]&[4] Auto Test Report Transmission
Options (see table on page 29)
N
See Table
N
See Table
N
See Table
N
See Table
[4] Dialing method
N Pulse
Tone
(DTMF)
[5]
Pulse ratio
(E.U. = Europe; N.A. = North America)
N 1:2 (E.U.)
1:1.5
(N.A.)
[5] Keypad beep on successful arming/
disarming report
Disabled
N Enabled
[6] Busy tone detection N Disabled
Enabled
[6] Alternate Dialing
Disabled
N Enabled
[7]
Switch to pulse dialing on 5
th
attempt
Disabled
N Enabled [7] Dial Tone Delay (if no dial tone)
Force dial
N Hang-up
[8]
Bell/siren upon communication
failure if system is armed
Disabled
N Enabled [8] Report zone restore
ON = On zone closure; OFF = On bell cut-off
Disabled
N Enabled