Digiplex DGP-NE96 - 21 - Programming Guide
NOTE 2: The TLM trouble event can only be used with DGP-NE96 control panel models that have two dialers.
NOTE 3: The TLM trouble event can only be used with DGP-NE96 control panel models that have one dialer.
NOTE 4: This event cannot be used for a module’s PGM programming.
*
: If a Keyswitch Input is used, the input must be defined as “Generates a Utility Key Event on Open” or “Generates a Utility Key Event on Open
and Close”. If a remote control is used, the remote control button must be defined as a Utility Key button.
: Actions that Activate a Utility Key Event:
** Keyswitch
Refer to the MG-RCV3 Reference and Installation Manual for remote control button programming instructions.
Utility Key Event
Actions
Keypad Utility Keys
Keyswitch Inputs
(definition = [3])
Keyswitch Inputs
(definition = [4])
Remote Control
Utility Key Event 1 [1] & [2] KS** Input 1 opens KS** Input 1 opens
Utility Key 1 RC button
Utility Key Event 2 [4] & [5] KS** Input 2 opens KS** Input 1 closes
Utility Key 2 RC button
Utility Key Event 3 [7] & [8] KS** Input 3 opens KS** Input 2 opens
Utility Key 3 RC button
Utility Key Event 4 [CLEAR] & [0] or [*] & [0] KS** Input 4 opens KS** Input 2 closes
Utility Key 4 RC button
Utility Key Event 5 [2] & [3] KS** Input 5 opens KS** Input 3 opens
Utility Key 5 RC button
Utility Key Event 6 [5] & [6] KS** Input 6 opens KS** Input 3 closes N/A
Utility Key Event 7 [8] & [9] KS** Input 7 opens KS** Input 4 opens N/A
Utility Key Event 8 [0] & [ENTER] or [0] & [#] KS** Input 8 opens KS** Input 4 closes N/A
Utility Key Event 9 N/A KS** Input 9 opens KS** Input 5 opens N/A
Utility Key Event 10 N/A KS** Input 10 opens KS** Input 5 closes N/A
Utility Key Event 11 N/A KS** Input 11 opens KS** Input 6 opens N/A
Utility Key Event 12 N/A KS** Input 12 opens KS** Input 6 closes N/A
Utility Key Event 13 N/A KS** Input 13 opens KS** Input 7 opens N/A
Utility Key Event 14 N/A KS** Input 14 opens KS** Input 7 closes N/A
Utility Key Event 15 N/A KS** Input 15 opens KS** Input 8 opens N/A
Utility Key Event 16 N/A KS** Input 16 opens KS** Input 8 closes N/A
Utility Key Event 17 N/A KS** Input 17 opens KS** Input 9 opens N/A
Utility Key Event 18 N/A KS** Input 18 opens KS** Input 9 closes N/A
N/A

N/A
Utility Key Event 31 N/A KS** Input 31 opens KS** Input 16 opens N/A
Utility Key Event 32 N/A KS** Input 32 opens KS** Input 16 closes N/A
Utility Key Event 33 N/A N/A KS** Input 17 opens N/A
Utility Key Event 34 N/A N/A KS** Input 17 closes N/A
N/A N/A
N/A
Utility Key Event 63 N/A N/A KS** Input 32 opens N/A
Utility Key Event 64 N/A N/A KS** Input 32 closes N/A