Digiplex DGP-NE96 - 31 - Programming Guide
Other Options
Schedule Tolerance Window
Telephone Line Monitoring (TLM) Options
(Section [3036]; options [1] & [2])
Auto-Test Report Transmission Options
(Section [3037]; options [3] & [4])
[1] [2] [3] [4]
OFF
OFF
ON
ON
OFF
ON
OFF
ON
Disabled (default)
When armed:
GENERATES AN AUDIBLE ALARM
When armed: GENERATES A TROUBLE
TLM silent alarm: BECOMES AN AUDIBLE ALARM
OFF OFF Transmit the test report code every time the days programmed
in section [3040] have elapsed at the time programmed in
section [3041] (default).
OFF ON When disarmed: Transmit test report code every time the
time programmed in section [3043] has elapsed.
When armed: Transmit test report code every time the time
programmed in section [3042] has elapsed.
ON OFF The control panel will transmit the test report code every hour
on the minute value programmed in section [3041] (the last
two digits). Note that the first two digits of section [3041] will
be ignored. For example, if 10:25 was programmed into
section [3041], the test report code would be transmitted at
the 25
th
minute of every hour, i.e. 11:25, 12:25, etc.
ON ON The test report code will be transmitted when any of the
conditions of the second and third options listed above
(options [3] = OFF and [4] = ON / options [3] = ON and [4] =
OFF) are met.
Section Data Description Default
[3039] __/__/__ ( x 1 minute) S
CHEDULE TOLERANCE WINDOW 000
Auto Test Report Settings
Section Data Description Default
[3040] __/__/__ ( x 1 day; 000 = disabled) A
UTO TEST REPORT 000
[3041] __/__ : __/__ Hrs (00-23) & Mins (00-59) A
UTO TEST REPORT TIME OF DAY 00 : 00
[3042] __/__/__ (000 - 255 x 1 minute) A
RMED REPORT DELAY 5 minutes
[3043] __/__/__ (000 - 255 x 1 minute) D
ISARMED REPORT DELAY 60 minutes
= Default setting
SECTION [3038]: Access Control Options
Option
OFF ON
[1] Access control feature
Disabled
N Enabled
[2]
Log “Request for Exit” in event
buffer*
Disabled
N Enabled
[3]
Log “Door Left Open Restore” in
event buffer
Disabled
N Enabled
[4]
Log “Door Forced Restore” in event
buffer
Disabled
N Enabled
[5]
Burglar alarm on forced door
Disabled
N Enabled
[6]
Skip exit delay when arming with
access card
Disabled
N Enabled
[7] Burglar alarm on door left open
Disabled
N Enabled
[8] Who has access during clock loss
All users
N Masters
* Since “Request for Exit” events can occur often, the Event
Buffer may fill up quickly.