046 Early to Arm by User
000 User Codes 001 to 255 001 to 255 001 to 255
001 User Codes 256 to 511 000 to 255 000 to 255
002 User Codes 512 to 767 000 to 255 000 to 255
003 User Codes 768 to 999 000 to 231 000 to 231
255 Any User Code Not Used Not Used
047 Late to Arm by User
000 User Codes 001 to 255 001 to 255 001 to 255
001 User Codes 256 to 511 000 to 255 000 to 255
002 User Codes 512 to 767 000 to 255 000 to 255
003 User Codes 768 to 999 000 to 231 000 to 231
255 Any User Code Not Used Not Used
048 Utility Key
000
Utility Key 001 to 064
†
*
001 to 064 001 to 064
255
Any Utility Key
†
*
Not Used Not Used
049 Request for Exit
000
255 = any Door
Number
Door Numbers
001 to 032 001 to 032
050 Access Denied 001 to 032 001 to 032
051 Door Left Open Alarm 001 to 032 001 to 032
052 Door Forced Alarm 001 to 032 001 to 032
053 Door Left Open Restore 001 to 032 001 to 032
054 Door Forced Open Restore 001 to 032 001 to 032
055 Intellizone Triggered
000 Zone Numbers 001 to 096 001 to 096
255 Any zone number Not Used Not Used
056 to 061 Future Use Future Use Future Use Future Use Future Use
062 Access Granted to User
000 User Codes 001 to 255 001 to 255 001 to 255
001 User Codes 256 to 511 000 to 255 000 to 255
002 User Codes 512 to 767 000 to 255 000 to 255
003 User Codes 768 to 999 000 to 231 000 to 231
255 Any User Code Not Used Not Used
063 Access Denied to User
000 User Codes 001 to 255 001 to 255 001 to 255
001 User Codes 256 to 511 000 to 255 000 to 255
002 User Codes 512 to 767 000 to 255 000 to 255
003 User Codes 768 to 999 000 to 231 000 to 231
255 Any User Code Not Used Not Used
064 Status 1
See Note 1
on page 21
Armed 000 000
Force Armed 001 001
Stay Armed 002 002
Instant Armed 003 003
Strobe Alarm 004 004
Silent Alarm 005 005
Audible Alarm 006 006
Fire Alarm 007 007
065 Status 2
See Note 1
on page 21
Ready 000 000
Exit Delay 001 001
Entry Delay 002 002
System in Trouble 003 003
Alarm in Memory 004 004
Zones Bypassed 005 005
Bypass, Master, Installer Programming 006 006
Keypad Lockout 007 007
066 Status 3
See Note 1
on page 21
Intellizone Delay Engaged
(see Note 4 on page 21)
000 000
Fire Delay Engaged 001 001
Auto Arm 002 002
Arming with Voice Module (set until
Exit Delay finishes)
003 003
Tamper 004 004
†: See page 21
*
: See page 21
Event Group Event Feature Group Feature Start # End #