GAS ANALYZER 319
3.0 SETTING UP THE EQUIPMENT
EQUIPMENT SETUP FOR SERVICE BAY TESTING
Equipment List
Before operating the PXA-1000 using your Diagnostic Tester and to ensure proper
operation, make sure the following components are available:
Diagnostic Tester
PXA-1000 Gas Analyzer
PXA-1000 analyzer hoses and probe assembly
DLC cable (for vehicle serial data)
Integrated power and I/P cable
Program card
VP-411 printer (optional)
AC/DC power supply (optional)
To set up the PXA-1000 and Tester, do the
following:
1.Locate a place to operate the PXA-1000 and
Tester.
Locate a convenient place to put your analyzer
that is out of your path for accessing the vehicle.
Verify that the hoses will reach the tailpipe of the
vehicle as well as allow you to control the PXA-
1000 with your Tester. Consideration also must be
made for location of the power source.
2.Connect the sampling hoses to the PXA-1000.
The sampling hoses are equipped with white
“quick-disconnect” connectors to allow you to
easily connect and disconnect the hoses from the
PXA-1000. Each port on the analyzer is labeled to
match the labels on the hose assembly for simple
hookup locations.
3.Supply power to the PXA-1000.
Begin by supplying power to both the Gas
Analyzer and the Tester. It is important that you
choose a power source that is best suited for your
testing needs. The power cable supplied with the
Gas Analyzer plugs into several possible power
sources using the proper adapters. Following is a
list of possible sources of power that you may use
to supply power to your Gas Analyzer and Tester.
CAUTION
CAUTION!
Route all cables and connectors away from hot exhaust
manifolds or tailpipes to avoid melting wires and connectors.
QUICK
DISCONNECT
CONNECTOR
CHECK VALVE
QUICK
DISCONNECT
CONNECTOR
(PRESS
DOWN)
FIGURE 3. Quick-Disconnect Connector