GAS ANALYZER 333
Press A ( to bypass the normal warm-up procedure. Only 50 seconds are required to
recalibrate the internal sensors to within an acceptable accuracy. This screen is displayed
on the tester during the 50-second warm-up bypass procedure.
Press h at this point to display the screen at the left.
It is important to note that a <MAINTENANCE REQ’D> status message is displayed on
the Data List following the 50-second warm-up bypass. This is due to the internal sensors
finishing their recalibration even though Data List parameters are displayed. The values
for HC, CO, and CO2 are not completely accurate at this point but are within an
acceptable range. After the Gas Analyzer has completed the recalibration, the
<MAINTENANCE REQ’D> status message disappears.