TESTER 45
DATA LINK
Press 5 to select the DATA LINK test from the SELF-TEST MENU. The DATA LINK
test checks for proper operation of the DLC cable.
ACTIVE KEY
e Runs the test.
The DATA LINK test result is displayed.
ACTIVE KEY
x Returns to the SELF-TEST MENU.
AUTOPROBE
Press 6 to select the Autoprobe test from the SELF-TEST MENU. The Autoprobe test
checks the internal circuits of the Autoprobe.
ACTIVE KEY
e Starts the Autoprobe switch test.
1. Press the Autoprobe switch to test.
2. PASSED” is displayed if the Autoprobe switch is operating properly.
ACTIVE KEY
e Starts the Autoprobe switch Self-Test.
NOTE
When this test is selected, you are instructed to install the 14-
pin DLC Self-Test Adapter on the end of the DLC cable.
Vista de pagina 56